Current Inventory > Liquid Chromatography

 
Stock Number: JMS0172
   
Manufacturer: Agilent
   
Model: 1100 Series HPLC Quaternary - FLD - Colcom - ALS - Degasser
   
Price: Inquire
   
   

Includes:

  • Solvent Tray
  • G1311A 1100 Series Quaternary Pump
  • G1379A 1100 Series Solvent Micro Degasser
  • G1313A 1100 Series Autosampler
  • G1316A Column Compartment
  • G1321A FLD Detector
  • Computer with Chemstation Software
  • Power Cords & Manuals

 

 

 

Submit Inquiry - fields marked with * are required

 

Name*:  
     
Company:  
     
E-Mail*:  
     
Phone*:  
     
Comments:  
     
    security code
Enter Security Code:

     
   
 

Description

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistions.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volitale solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control.  The gradient formation is performed by a low pressure gradient valve. System specifications include:

  • Setable Flow Range: 0.001 - 10ml/min - in 0.001ml/min increments
  • Flow Range: 0.2 - 10.0 ml/min
  • Recommended pH Range: 1.0 - 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure   
The HP/Agilent G1379A Micro Degasser  comprises a 4-channel vacuum container, including 4 micro structured membranes and a vacuum pump.
  • Maximum flow rate: 0-10 ml/min per channel, 5-10 ml/min at reduced degassing performance.
Agilent 1100 Series G1313A Autosampler Overview
  • Communications: Controller Area Network (CAN), GPIB (IEEE-448), Serial (RS232C)
  • GLP features: Early maintenance feedback (EMF), records of maintenance and errors
  • Safety features: Leak detection, safe leak handling, and error detection and display
  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Agilent 1100 Series G1316A Thermostated Column Compartment Overview:
The Agilent 1100 Series G1316A thermostatted column comparment is built with two heat exchangers for solvent pre-heating, automated column identification module and CAN cable.
  • Temperature Range 10° below ambient to 80° C
  • Temperature Stability ± 0.15°C
  • Temperature Accuracy ± 0.8°C
  • Column Capacity Three 30cm columns
  • Warm-up/Cool Down 5 mins from ambient to 40°C
The  1100 Series G1321A fluorescence detector (FLD) is a standalone detector capable of integrating with any 1100 Series system.
Featuring superior sensitivity for lower detection limits at any combination of excitation and emission wavelengths, simplified optics and a reference system improve baseline stability.

G1321A Fluorescence Detector

  • Single wavelength operation: 10 fg anthracene LOD, Ex 250 nm, Em 400 nm H20 >500 Raman, Ex 350 nm, Em 397 nm, dark value 450 nm, standard flow cell
  • Dual wavelength operation: H20 > 300 Raman, Ex 350 nm, Em 397 nm and Ex 350, em 450 nm, standard flow cell
  • G1321A Fluorescence Light source: 20 Watt Xenon flash lamp (Normal mode: 20 Watts / Economy mode: 5 Watts)
  • Pulse frequency: 365 Hz for signal mode, 73 Hz for economy mode
  • Wavelength repeatability: ±0.2 nm
  • G1321A Fluorescence Wavelength accuracy: ±3 nm