Current Inventory > Liquid Chromatography

 
Stock Number: JMS0175
   
Manufacturer: Agilent
   
Model: 1100 Series HPLC Quaternary - DAD - Colcom - ALS - Degasser
   
Price: Inquire
   
   

Includes:

  • Solvent Tray
  • G1311A 1100 Series Quaternary Pump
  • G1379A 1100 Series Solvent Micro Degasser
  • G1313A 1100 Series Autosampler
  • G1316A Column Compartment
  • G1314A VWD Detector
  • Computer with Chemstation Software
  • Power Cords & Manuals

 

 

 

Submit Inquiry - fields marked with * are required

 

Name*:  
     
Company:  
     
E-Mail*:  
     
Phone*:  
     
Comments:  
     
    security code
Enter Security Code:

     
   
 

Description

Agilent G1311A Quaternary Pump

The G1311A is an optimized design ensuring virtually pulse-free and stable solvent flow with dual floating pistons.  An inlet valve electronically activated and synchronized to piston stroke eliminates vapor formation with volatile solvents and is maintenance free.  Instrument comes equipped with four solvent inlets with built-in gradient control.  The gradient formation is performed by a low pressure gradient valve. System specifications include:

  • Setable Flow Range: 0.001 - 10ml/min - in 0.001ml/min increments
  • Flow Range: 0.2 - 10.0 ml/min
  • Recommended pH Range: 1.0 - 12.5, solvents with pH > 2.3 should not contain acids which attack stainless steel
  • Gradient Formation: Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve. Delay volume 800-1100µl, depending on back pressure
Agilent G1379A Micro Degasser               
  • The HP/Agilent G1379A Micro Degasser  comprises a 4-channel vacuum container, including 4 micro structured membranes and a vacuum pump.
  • Maximum flow rate: 0-10 ml/min per channel, 5-10 ml/min at reduced degassing performance.
Agilent 1100 Series G1313A Autosampler    
  • Communications: Controller Area Network (CAN), GPIB (IEEE-448), Serial (RS232C)
  • GLP features: Early maintenance feedback (EMF), records of maintenance and errors
  • Safety features: Leak detection, safe leak handling, and error detection and display
  • Injection range: From 0.1 – 100 µl in 0.1 µl increments
  • Replicate injections: From 1 – 99 from one vial
  • Injection cycle time: Typically 50 s, depending on draw speed and volume
  • Sample capacity: 100 × 2 ml vials in tray
Agilent 1100 Series G1316A Thermostatted Column Compartment

The Agilent 1100 Series G1316A thermostatted column compartment is built with two heat exchangers for solvent pre-heating, automated column identification module and CAN cable.
  • Temperature Range 10° below ambient to 80° C
  • Temperature Stability ± 0.15°C
  • Temperature Accuracy ± 0.8°C
  • Column Capacity Three 30cm columns
  • Warm-up/Cool Down 5 mins from ambient to 40°C
  • Different Types Communication Ports CAN, GPIB, RS-232C, APG Remote

Agilent G1314A VWD - Variable Wavelength Detector

The Agilent G1314A VWD Detector 1100 Series variable wavelength detector (VWD) lowers detection limits with simplified optics for high sensitivity, low baseline drift and wide linear range. The Agilent 1100 Series G1314A Variable Wavelength Detector (VWD) has a wide linear range for reliable simultaneous quantitation of main, side  products and impurities. Minimum baseline noise with the highest baseline stability for lowest detection limits.

  • Wavelength range 190 - 600 nm
  • Wavelength accuracy ± 1 nm, self calibration with deuterium lines, verification with Holmium oxide filter
  • Detector type Double beam
  • Light source Deuterium lamp
  • Short-term noise ± 0.75 x 10-5AU at 254 nm
  • Drift 3 x 10-4 AU/h at 254 nm
  • Linearity > 2 AU upper limit
  • Slit width 6.5 nm
  • Flow cells Standard: 14µl, volume, 10 mm cell path length 40 bar (588 psi) pressure max.
  • Semi-micro: 5µl, volume, 6 mm cell path length 40 bar ( 588 psi) pressure max.
  • Micro: 1µl, volume, 5 mm cell path length 40 bar (588 psi) pressure max.
  • High pressure: 14µl, volume, 10 mm cell path length 400 bar (5880 psi) pressure max.
  • Time programmable Wavelength, polarity, peak width, lamp on/off.